Nuaire - WM1 Unit

More Views

Interest Free EMI
Nuaire - WM1 Unit
£666.96 including VAT Excluding VAT £555.80
Nuaire - MRXBOX95-WM1
Description

Details

Nuaire - MRXBOX95-WM1

Cost efficient and good value for money MVHR unit

The MRXBOX95-WM1 is a wall or cupboard mounted MVHR system designed specifically for small sized houses and apartments.

It incorporates the latest generation of low voltage DC fans, counter flow heat exchanger and easily accessible controls. The heat exchanger block can recover up to 93% of the heat which would normally be wasted, giving this product a high score on SAP Appendix Q and helping you meet building regulations.

  • Up to 93% Heat recovery 
  • 120m3/h @100pa suitable for houses with Max floor area of 80m2
  • Specific fan power as low as 0.59 wls
  • 100% Adjustable air flow rates
  • G3 filters
  • Frost protection
  • Multiple control options
  • SAP Appendix Q listed
  • 5 Year Warranty
  • Developed and manufactured in th UK
  • 4 x 125 spigots
  • Dimensions (mm)601 X 500 X 288

Also available with summer Bypass (AB-WM1)

Digital controller also available (VSC)

Benefits of working with BPC Ventilation

  • In-House design service
  • Largest range of heat recovery systems
  • Technical support including live chat
  • Specialists in easy to install DIY systems
  • All products in stock in our own warehouse
  • Large showroom with working units on display
  • Free delivery to any UK Mainland or Location
  • Delivery also available to any worldwide location
  • Installer network throughout the UK and Ireland
  • Authorised suppliers and distributions for all products
  • All systems comply to all the latest building control regulations 
Technical Specification

Technical Specification tab

Nuaire WM1 technical page

Download Documentation
Nuaire WM1 Catalogue
Nuaire WM1 installation
Further Information

How to install a Nuaire WM1 MVHR unit


Nuaire WM1 Wiring Requirements



  • 3amp switched spur beside unit

  • Optional boost switch - 4 core 1.0mm cable from recessed single box to unit (recommended if bathrooms are further than 5 meter from unit)

  • Digital controller- Comes complete with 15 meter of 6 core alarm cable with a RJ45 connection


Commissioning



  • The low and high speed levels can be adjusted using the digital control

  • further controls include- night time set speed set back - timed boost- sensor control - humidity sensor control - tempature control - summer bypass control - fault indication - filter indicator


Installation Guide


Nuaire WM1 1st Fix



  1. Position Nuaire WM1 unit proverbially on a wall or vertical timber frame with provided wall bracket

  2. Install wiring for controllers (see top of page for further details)

  3. Install condensation drain from unit to internal or external drain

  4. Install wall /Soffit vents or roof vents (Minimum 1.5 meter apart) Pipes are 125mm diamater

  5. Position distribution boxes in the chosen location (proverbially in a central location minimising duct lengths )

  6. Install silencer (if specified) to air supply distribution box

  7. Install solid rigid ductwork and between distribution boxes and MVHR unit, (If possible allow for insulated flexible ductwork for final connections of MVHR unit )

  8. Install radial pipe into the distribution box ,

  9. Cut to length and install pipe into ceiling plenum, (insure you install rubber seal onto pipe) secure pipe in place with fixing band or pipe clips


Warning! There can be either one or two pipes going from the distribution box to the plenum depending on the required airflow , Always check plan that will indicate 1 or 2 pipes Install insulated rigid or insulated flexible ductwork to external vents Seal all open pipes to prevent debris and moisture ingress


 


Nuaire WM1 2nd fix



  1. Trim ceiling Plenums to height of plasterboard (Easier to do before plastering ceilings)

  2. Install air valves to plenums (slightly open valve by two turns)

  3. Install all controllers

  4. Check that condensation drain has been fitted

  5. Switch unit on and follow the set up procedures

  6. Check air flow rates and commission system



Initial Design -


Pre designed plan - Please follow the plan ensuring the correct number of pipes to each area - Please note the plan is only a guide and you may have to reroute pipe work differently and reposition valves to suit layout of rooms


No Plan - If a design is not possible due to renovation, Retrofit or properties with multiple obstacles simply follow the listed recommendations


We would recommend that you



  • Install 2 x pipes from the distribution box to the room air plenum if air flow requirement exceed 10 L/s or if length over 15 meters  

  • Install 2 x pipes from the distribution box to the air extract plenum in the main shower rooms and Kitchen

  • All other areas only require a single pipe from the distribution box to the room air plenum

  • Radial ductwork is suitable to be fitted below your loft insulation providing superior heat retention Insulate any ductwork or Manifold/ Distribution boxes with a minimum of 25mm thermal duct wrap that go above insulation in unheated attic spaces

  • Slim-line manifolds are suitable for installation to concrete ceilings and only require a 100mm service void

  • Position supply plenums approx. 500mm from corner of wall (avoid areas above beds and wardrobes)

  • Position extraction plenums to outside of showers and above kitchen sink (not cooker)

  • Only extract from a room with a open appliance (stove) if there is a supply with equal or higher airflow

Reviews

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.