Vent Axia Sentinel Kinetic BH Heat Recovery Unit

More Views

Interest Free EMI
Vent Axia Sentinel Kinetic BH Heat Recovery Unit
Inc Vat £1,398.00 Excluding VAT £1,165.00
Vent Axia Sentinel Kinetic BH heat recovery unit -443319

* Required Fields

£0.00 including VAT Excluding VAT £0.00
Description

Details

Vent Axia Sentinel Kinetic BH heat recovery unit -443319 

The Lo-Carbon Sentinel Kinetic BH is the UKs bestselling heat recovery unit for people looking for a top quality unit at a realistic cost. Suitable for houses up to 150 m2 and meets the latest requirements of the Building Regulations ADF and ADL for whole house system ventilation:

KEY FEATURES:

  • Suitable for houses up to 150 m2
  • Up to 90% heat recovery
  • Extra low energy use
  • Mechanical summer by-pass
  • Internal humidity sensor
  • Digital control
  • 5 Year warranty
  • Vertical or horizontal connections
  • Left or right-hand configuration

Filtration

2 x G4 with the option of a F7 pollen intake filter

Controllability

The Lo-Carbon Sentinel Kinetic models have 3 fully adjustable speeds and a purge setting (maximum flow). Provided with the unit is a digital controller that can be used to pre-set the speeds to any required airflow within the performance range

Boost can be achieved with almost any type of sensor or switch including momentary 

Integral Humidity Sensor

The integral humidity sensor (models with H suffix) increases speed in proportion to relative humidity levels, saving energy and reducing noise.The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature

Construction

The outer enclosure is constructed of PVC with the inner body being constructed of EPP

Motors

The unit has 2 x low energy, high efficiency EC/DC motors

Installation
Spigot Options The combination of spigot options allows installation in confined locations. If vertical and horizontal connection is required on the same outlet/inlet, additional spigots can be supplied. The condensate drain can be taken out through the back, side or bottom of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation

ACCESSORIES:

In addition to a choice of compatible ducting systems a full range of controls, sensors, in-line silencers, floor/wall/ceiling inlet and outlet diffusers are available to complete the installation.

Benefits of working with BPC Ventilation

  • Authorised Vent-Axia distributors
  • In-House design service
  • In-House Technical support
  • Specialists in easy to install DIY systems
  • 1000s of products in stock in our own warehouse
  • Large showroom with working units on display
  • Installer network throughout the UK and Ireland
  • All systems comply to all the latest building control regulations 
  • 0% Finance available 
Technical Specification

Technical Specification tab

Model

Vent Axia Kinetic BH

Heat Recovery efficiency %

90%

Digital Controller

yes

Boost Switch control

Yes - Momentary

Interactive control

No

Humidity control

Internal and optional external sensor

Airflow rate Max m3/h

280

Airflow rate @ 100Pa m3/h

245

Max dwelling size M2

150 (uk)

Max room extraction

Kitchen plus 4 extraction points

Specific fan power (lowest)

0.59

Dimensions W x H x D (mm)

550 x 550 x 285

Weight

15kg

Filtration

Yes 2 x G4 (optional 1xF7)

Summer Bypass 

Yes

Frost protection 

Yes

Sound level @3m db.(a)

16 to 39

Mounting

Ceiling or loft

Ductwork connections

wall - floor

Duct Diameter

4 x125mm

Condensate drain

yes

warranty

5-year

Country of manufacture

UK

Heat exchanger

Counterflow heat exchanger (PVC)

Available room sensors

Humidity, Timer, Pir

BMS - KNX

Yes - BMS

SAP Appendix Q

Yes

Fireplace mode

No

Alarm system integration

Yes

Passive House

No

ERP rating

A

SKU

RHS -443319   LHS- 443319L

Download Documentation
Vent Axia Kinetic BH Catalogue
Vent Axia Kinetic Installation instructions
Further Information

How to install a Vent Axia Kinetic BH


Vent Axia BH Wiring Requirements



  • 3amp switched spur beside unit

  • Digital controller- Comes complete with 15 meter of 6 core alarm cable with a RJ45 connection

  • Optional boost switch - 3 core 1.mm cable from recessed single box to unit(recommended if bathrooms are further than 10 meter 

  • Further optional include - light switch, vent-wise controller, 


Commissioning



  • The low and high speed levels can be adjusted using the digital control

  • further controls include- night time set speed set back - timed boost- sensor control - humidity sensor control - tempature control - summer bypass control - fault indication - filter indicator


Installation Guide


Vent Axia BH 1st Fix



  1. Position vent axia BH unit proverbially on a wall or vertical timber frame with provided wall bracket

  2. It is possible to take pipes from either the top of side of unit

  3. Duct connections RHS unit -rear left is extract from house-front left is supply air to living areas- rear right is air intake from outside - front right is air to outside

  4. Install wiring for controllers (see bottom of page for further details)

  5. Install condensation drain from unit to internal or external drain

  6. Install wall /Soffit vents or roof vents (Minimum 1.5 meter apart) Pipes are 125mm diamater

  7. Position distribution boxes in the chosen location (proverbially in a central location minimising duct lengths )

  8. Install silencer (if specified) to air supply distribution box

  9. Install solid rigid ductwork and between distribution boxes and MVHR unit, (If possible allow for insulated flexible ductwork for final connections of MVHR unit )

  10. Install radial pipe into the distribution box ,

  11. Cut to length and install pipe into ceiling plenum, (insure you install rubber seal onto pipe) secure pipe in place with fixing band or pipe clips


Warning! There can be either one or two pipes going from the distribution box to the plenum depending on the required airflow , Always check plan that will indicate 1 or 2 pipes Install insulated rigid or insulated flexible ductwork to external vents Seal all open pipes to prevent debris and moisture ingress


 


Vent Axia BH 2nd fix



  1. Trim ceiling Plenums to height of plasterboard (Easier to do before plastering ceilings)

  2. Install air valves to plenums (slightly open valve by two turns)

  3. Install all controllers

  4. Check that condensation drain has been fitted

  5. Switch unit on and follow the set up procedures

  6. Check air flow rates and commission system



Initial Design -


Pre designed plan - Please follow the plan ensuring the correct number of pipes to each area - Please note the plan is only a guide and you may have to reroute pipe work differently and re position valves to suit layout of rooms


No Plan - If a design is not possible due to renovation, Retrofit or properties with multiple obstacles simply follow the listed recommendations


We would recommend that you



  • Install 2 x pipes from the distribution box to the room air plenum if air flow requirement exceed 10 L/s or if length over 15 meters  

  • Install 2 x pipes from the distribution box to the air extract plenum in the main shower rooms and Kitchen

  • All other areas only require a single pipe from the distribution box to the room air plenum

  • Radial ductwork is suitable to be fitted below your loft insulation providing superior heat retention Insulate any ductwork or Manifold/ Distribution boxes with a minimum of 25mm thermal duct wrap that go above insulation in unheated attic spaces

  • Slim-line manifolds are suitable for installation to concrete ceilings and only require a 100mm service void

  • Position supply plenums approx. 500mm from corner of wall (avoid areas above beds and wardrobes)

  • Position extraction plenums to outside of showers and above kitchen sink (not cooker)

  • Only extract from a room with a open appliance (stove) if there is a supply with equal or higher airflow