0% Finance now available. Pay by instalments on orders over £500!
Send Your Plan

Vent Axia Kinetic Advance S Heat Recovery Unit

More Views

Interest Free EMI
Vent Axia Kinetic Advance S Heat Recovery Unit
£1,734.00 including VAT Excluding VAT £1,445.00
Vent Axia Kinetic Advance S heat recovery unit - 405215
Description

Details

Vent Axia Sentinel Kinetic Advance S heat recovery unit – 405215

The Sentinel Kinetic® Advance from Vent-Axia is the next generation of heat recovery ventilation systems. It is designed to offer the highest level of comfort, quietness and control available ensuring the best possible customer experience.

The highly sculpted interior surfaces, designed using the latest CFD techniques, ensures airflows are maximised through the unit minimising noise and energy use. This feature alone provides an experience which we are confident will delight home owners and fulfil our ambition of providing the most discrete and efficient ventilation available. With the widest range of options available,

Suitable for houses up to 220 m2 and meets the latest requirements of the Building Regulations ADF and ADL for whole house system ventilation:

KEY FEATURES:

  • Vent Axia Advance Heat S recovery unit
  • Suitable for houses up to 220 m2
  • Up to 93% heat recovery
  • Extra low energy use
  • Mechanical summer by-pass
  • Internal humidity sensor
  • Digital touch screen control
  • 5 Year warranty
  • Left or right-hand configuration
  • Pre-commissioning via USB
  • Left/Right handing through the controller
  • G3, M5 and F7 filter options

Filtration

The Advance system the most flexible solution available on the market. Optimisation has been targeted in every aspect of the design to ensure that it really does improve quality of life. Whatever the outside environment, we a have a method to help reduce air pollution from entering the living space. Our range of filter options, up to and including F7, ensure that even homes in heavily urbanised areas have the opportunity to filter out the impurities and help protect their family from respiratory issues.

Controllability

Should you want to run the system at certain times and at certain speeds, all the options are available for you. With the provided touch screen programmable controller, it is possible to boost the unit if required, for example during hot periods in the summer, or even reduce the speed if needed, perhaps when a baby is due to go to bed. Whatever the situation, Advance can be made to operate as needed. At the same time, automatic functions such as frost protection and summer bypass even have a choice of algorithms designed to suit different climates and lifestyles

Boost can be achieved with almost any type of sensor or switch including momentary.

Integral Humidity Sensor

The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature

Construction

The outer enclosure is constructed of PVC with the inner body being constructed of EPP

Motors

The unit has 2 x low energy, high efficiency EC/DC motors

Installation
You can change the spigot configuration electronically using the touch screen controller

The Advance unit can  

The condensate drain can be taken out through the back, side or bottom of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation

ACCESSORIES:

In addition to a choice of compatible ducting systems a full range of controls, sensors, in-line silencers, floor/wall/ceiling inlet and outlet diffusers are available to complete the installation.

Benefits of working with BPC Ventilation

  • Authorised Vent-Axia distributors
  • In-House design service
  • In-House Technical support
  • Specialists in easy to install DIY systems
  • 1000s of products in stock in our own warehouse
  • Large showroom with working units on display
  • Installer network throughout the UK and Ireland
  • All systems comply to all the latest building control regulations 
  • 0% Finance available 
Technical Specification

Technical Specification tab

    Vent Axia Kinetic Advance Technical Data

Model

Vent Axia Sentinel Kinetic Advance S

Heat Recovery efficiency %

93%

Digital Controller

Yes (touch screen)

Boost Switch control

Yes - Momentary

Interactive control

No

Humidity control

Internal and optional external sensor

Airflow rate Max m3/h

415

Airflow rate @ 100Pa m3/h

370

Max dwelling size M2

220 (uk)

Max room extraction

Kitchen plus 5 extraction points

Specific fan power (lowest)

0.38

Dimensions W x H x D (mm)

660 x 760 x 443

Weight

32kg

Filtration

Yes 2 x G4 (optional 1xF7)

Summer Bypass 

Yes

Frost protection 

Yes

Sound level @3m db.(a)

15-42

Mounting

Wall / floor

Ductwork connections

Top

Duct Diameter

4 x125mm

Condensate drain

yes

warranty

5-year

Country of manufacture

UK

Heat exchanger

Counterflow heat exchanger (PVC)

Available room sensors

Humidity, Timer, Pir

BMS - KNX

Yes - BMS

SAP Appendix Q

Yes

Fireplace mode

No

Alarm system integration

Yes

Passive House

No

ERP rating

A+

SKU

405215

Download Documentation
Vent Axia Advance Catalogue
Further Information

How to install a Vent Axia Advance S


Vent Axia advance Wiring Requirements



  • 3amp switched spur beside unit

  • Digital controller- (available soon) Comes complete with 15 meter of 6 core alarm cable with a RJ connection


Commissioning



  • The low and high speed levels can be adjusted using the digital control

  • further controls include- night time set speed set back - timed boost- sensor control - humidity sensor control - tempature control - summer bypass control - fault indication - filter indicator


Installation Guide



  1. Position vent axia Advance unit on floor or ceiling

  2. Install wiring for controllers (see bottom of page for further details)

  3. Install condensation drain from unit to internal or external drain

  4. Install wall /Soffit vents or roof vents (Minimum 1.5 meter apart) Pipes are 125mm diamater

  5. Position distribution boxes in the chosen location (proverbially in a central location minimising duct lengths )

  6. Install silencer (if specified) to air supply distribution box

  7. Install solid rigid ductwork and between distribution boxes and MVHR unit, (If possible allow for insulated flexible ductwork for final connections of MVHR unit )

  8. Install radial pipe into the distribution box ,

  9. Cut to length and install pipe into ceiling plenum, (insure you install rubber seal onto pipe) secure pipe in place with fixing band or pipe clips


Warning! There can be either one or two pipes going from the distribution box to the plenum depending on the required airflow , Always check plan that will indicate 1 or 2 pipes Install insulated rigid or insulated flexible ductwork to external vents Seal all open pipes to prevent debris and moisture ingress


 


Vent Axia 2nd fix



  1. Trim ceiling Plenums to height of plasterboard (Easier to do before plastering ceilings)

  2. Install air valves to plenums (slightly open valve by two turns)

  3. Install all controllers

  4. Check that condensation drain has been fitted

  5. Switch unit on and follow the set up procedures

  6. Check air flow rates and commission system



Initial Design -




  1. Pre designed plan - Please follow the plan ensuring the correct number of pipes to each area - Please note the plan is only a guide and you may have to reroute pipe work differently and reposition valves to suit layout of rooms


    No Plan - If a design is not possible due to renovation, Retrofit or properties with multiple obstacles simply follow the listed recommendations


    We would recommend that you



    • Install 2 x pipes from the distribution box to the room air plenum if air flow requirement exceed 10 L/s or if length over 15 meters  

    • Install 2 x pipes from the distribution box to the air extract plenum in the main shower rooms and Kitchen

    • All other areas only require a single pipe from the distribution box to the room air plenum

    • Radial ductwork is suitable to be fitted below your loft insulation providing superior heat retention Insulate any ductwork or Manifold/ Distribution boxes with a minimum of 25mm thermal duct wrap that go above insulation in unheated attic spaces

    • Slim-line manifolds are suitable for installation to concrete ceilings and only require a 100mm service void

    • Position supply plenums approx. 500mm from corner of wall (avoid areas above beds and wardrobes)

    • Position extraction plenums to outside of showers and above kitchen sink (not cooker)

    • Only extract from a room with a open appliance (stove) if there is a supply with equal or higher airflow



Reviews