0% Finance now available. Pay by instalments on orders over £500!
Send Your Plan

Vent Axia Sentinel Multivent H Unit with Humidity Sensor

More Views

Interest Free EMI
Vent Axia Sentinel Multivent H Unit with Humidity Sensor
Inc Vat £444.00 Excluding VAT £370.00
Vent Axia Sentinel Multivent H with Humidity Sensor and Digital Controller
£0.00 including VAT Excluding VAT £0.00
Description

Details

Vent Axia Sentinel Multivent H with Humidity Sensor and Digital Controller 445655

Top of the range Continuous running mechanical extract system with integral humidity sensor and integral digital control panel, designed for the simultaneous ventilation of separate ares in the home or as a multipoint extraction system for a wide range of commercial applications. The integral humidity sensor increases fan speed in proportion to relative humidity levels, saving energy and reducing noise.

Please note - You can purchase the MEV unit with or without the ductwork on this listing and the Unit and room ducting kits include the MEV unit

KEY FEATURES:

  • Internal Humidity sensor
  • Max Airflow of 450m3/h
  • Integral LCD display allows the installer to select appropriate low, normal and boost speeds to meet demand
  • Energy efficient EC/DC motors - 1/3 less energy lost to heat than a conventional AC motor
  • Ultra quiet - acoustically lined for low noise levels
  • Best in class Specific Fan Power (SFP) as low as 0.16 wls
  • Dimensions (mm) 340 long x 310 wide x 249 high
  • Fitted with four extract 125 or 100mm diameter spigots allowing quick connection to ducts
  • Demand Control - enables precise ventilation rate, is set in 1% increments based on property size
  • Manual and automatic control options
  • Integral adjustable overrun timer and delay on timer
  • Plug-n-Play automatic sensor detection
  • Switched live and SELV connections
  • Dry Out setting – Option set at installation, Sentinel Multivent will run on boost for 1 week to assist in removing moisture
  • Optional Wireless Control – up to 4 controllers on any one system
  • Recognised in SAP Appendix Q
  • Complies with Building ADF (System 3)
  • Option of wall, ceiling and loft mounting
  • Fully serviceable unit with all parts accessible
  • 2 year standard or optional 5-year parts warranty: 

Humidity Sensor

The integral humidity sensor (Sentinel Multivent H) increases fan speed in proportion to relative humidity levels, saving energy and reducing noise
The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room
Night time relative humidity increment setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature

Controllability

• Demand Control - enables precise ventilation rate, is set in 1% increments based on property size
• Integral LCD display allows the installer to select appropriate low, normal and boost speeds to meet demand
• Manual and automatic control options
• Integral adjustable overrun timer and delay on timer
• Plug-n-Play automatic sensor detection
• Switched live and SELV connections
• Dry Out setting – Option set at installation, Sentinel Multivent will run on boost for 1 week to assist in removing moisture
• Optional Wireless Control – up to 4 controllers on any one system

Construction

PVC outer casing with an acoustic lining is included as standard, ensuring minimum noise levels.

Motors

  • Energy efficient EC/DC motors - 1/3 less energy lost to heat than a conventional AC motor

Installation

ceiling, wall or floor Installation is recommended 

ACCESSORIES:

Switches, wireless controller, co2, Humidity, room sensor

Benefits of working with BPC Ventilation

  • Authorised Vent Axia distributors
  • In-House design service
  • In-House Technical support
  • Specialists in easy to install DIY systems
  • 1000s of products in stock in our own warehouse
  • Large showroom with working units on display
  • Installer network throughout the UK and Ireland
  • All systems comply to all the latest building control regulations 
  • 0% Finance available 
Ducting Kits

Ducting kits

Vent Axia Sentinel Multivent H Kit- VSMHMEVPK

List of Products in Kit

 

part numberDescription2 point kit3 point kit4 point kit5 point kit
445655Sentinel Multivent H1111
MW124125mm Metal extract valve2345
C125125mm pipe connector 1 2 3 4
GPVC125W125mm PVC external grille (white) 1 1 1 1
IFD125125mm Insulated flexible ducting X 10 Meter 1 2 2 3
ST75Roll 75mm x 10m silver foil tape  1 1 1 1
JC160Jubilee clip 100-150mm (pack 10) 1 1 12
T125125mm T piece0012

 

 

Technical Specification

Technical Specification

Technical Specification for Vent Axia Sentinel Multivent H with Humidity Sensor 

DIMENSIONS:

Dimensions (mm)

ABCDEFGHIJ
34072.5251536021431026015085

 

Further Information

Further Information

Wiring to the Sentinel Multivent

  • If you want the fan to switch to boost speed when a light is turned on, connect the switched live connection from the lighting circuit to the LS connection on the power supply board. When commissioning the unit, a delay on timer and an overrun timer can be selected and adjusted in the software using the buttons and screen. See Commissioning section on page 6 of this document for details.
  • The switched live output (230V) from any other switch or controller, (such as a simple pullcord or push button switch, humidistat or PIR detector) can be connected to the LS terminal instead of connecting to a lighting circuit.
  • Important: Use 4-core, low voltage, twisted pair, telecoms type cable for accessories (Vent-Axia part number 459931). Connect any outputs from accessories / controls that you want to use to the terminal block on the motherboard. Again, use the cable clamp provided. Remove the knock out from the cover. The connections for accessories on the motherboard are powered by a SELV (Safety Extra Low Voltage) power supply.
  • Controllers or switches that switch a volt-free relay can be connected to the volt-free terminals on the motherboard. When the circuit between the two terminals is closed, (when a connected switch is in the 'On' or 
  • 'Closed' position, for example), the fan will switch to Boost speed. There are no delay on or overrun timers with the volt-free connection as the controller should determine when the fan is running at Boost or Normal speeds. Use the LS connection described above if you want a timer.
  • Multiple controllers or switches can be connected to the volt-free terminals when connected in parallel and the cable lengths are not long.
  • Connecting a switch / relay between the Com and Hi terminals will have the same effect as the connecting to the volt-free connections.
  • The Lo, Hi and Com terminals can be used to connect a three position switch. Connect Com to the common terminal of the switch, Lo to Lo, Low or position 1 and Hi to Hi, High, Boost or position 3. No connection to Normal or position 2 is required. If there is no current to the Lo or Hi terminals on the motherboard, the fan will default to Normal speed.
  • The Sentinel Multivent can also be controlled by an optional battery powered, wireless boost switch (437827) when the optional wireless receiver PCB (437599), (available in wireless boost and receiver kit 439352), is connected to the motherboard. Screw the wireless receiver PCB to the scroll in the position indicated above and plug it in to the connector on the motherboard marked CO . The system address is set by the 6-way DIP switch on the PCBs.
  • The system address needs to match on the receiver PCB and all transmitter PCBs for any one system. For multiple systems in close proximity to each other, the system addresses need to be different in order to identify which transmitters are controlling which fans. The transmitter PCBs also have a 2-way DIP switch to set the transmitter address. Up to four transmitters can be used to control any one Sentinel Multivent. The transmitter address needs to be different for each transmitter in a system.
  • If a number of different accessories are calling for the fan to run at different speeds, the fan will run at the fastest speed called for.

 

 

 

Reviews